A commercial electrical inspection in Melbourne covers more than replacing light globes - it includes switchboard compliance against AS/NZS 3000, verification of test and tag currency, AFSS requirements, RCD testing, and emergency lighting function. For businesses with compliance obligations, here's what the inspection involves and what the report means for your legal exposure.

Why commercial electrical compliance is different

Residential and commercial electrical obligations overlap in some areas and diverge significantly in others. For commercial premises in Victoria, the relevant framework includes:

  • AS/NZS 3000 (Wiring Rules) - the baseline for all electrical installation work.
  • AS/NZS 3760 (Test and tagging of in-service electrical equipment).
  • Occupational Health and Safety Act 2004 (Vic) - employer duty to ensure electrical safety.
  • Annual Fire Safety Statement (AFSS) obligations for strata and commercial buildings - includes emergency lighting and exit signs.
  • WorkSafe Victoria guidance on electrical risk management.

Switchboard compliance audit

A commercial switchboard audit assesses the board against current requirements, noting any non-compliances. This typically involves:

  • Identification of all circuit protection devices - MCBs, RCDs, RCBOs.
  • Verification that all circuits serving general purpose outlets are RCD-protected (AS/NZS 3000 clause 2.6.3).
  • Thermal imaging of the switchboard where accessible - identifies hot joints or overloaded conductors before they fail.
  • Checking that the board is correctly labelled and the diagram is current.
  • Verification of earthing continuity and main earth connection.
  • RCD trip-time testing (RCDs must operate within 300 ms at rated current).

The Energy Safe Victoria guidance on commercial electrical safety is the definitive reference for what constitutes a compliant commercial installation in Victoria. All work identified in the inspection as non-compliant must be rectified by a licensed electrical contractor, with a Certificate of Electrical Safety issued on completion.

Test and tag requirements in Victoria

What is test and tag?

Test and tag is the inspection and electrical testing of portable electrical appliances in a workplace. Under AS/NZS 3760, a licensed or competent tester uses a PAT (portable appliance tester) to check insulation resistance, earth continuity, and polarity of each portable appliance. A compliant tag is affixed showing the test date, pass/fail result, and next test due date.

How often is testing required?

EnvironmentRecommended testing frequency
Construction sites and workshops (mobile equipment)3 months
Factories and manufacturing6 months
Office and retail (low-risk)12 months
Hire equipment (before hire)Before each hire
Repaired electrical equipmentBefore return to service

There is no single mandated frequency for all workplaces - the AS/NZS 3760 frequency table is risk-based. However, if a workplace injury or fire occurs and you cannot demonstrate current test and tag records, WorkSafe Victoria will treat the absence of testing as a contributing factor in the incident investigation.

Emergency lighting and exit signs

Emergency lighting and exit signs in commercial buildings must be tested per AS/NZS 2293.2. This includes:

  • Monthly lamp function test (battery backup lamp illuminates when mains is simulated off).
  • Annual 90-minute discharge test (confirms battery will sustain illumination for the full 90 minutes required).
  • Records maintained and available for inspection.

Strata buildings subject to AFSS requirements must include emergency lighting compliance in their annual essential services maintenance records. Building occupiers who fail to maintain these records can face penalty notices from the Metropolitan Fire Brigade and the Victorian Building Authority.

What the inspection report looks like

A commercial electrical inspection report will typically:

  • List each item inspected with pass/fail/advisory status.
  • Classify each defect as either an immediate hazard (rectify before further use), a compliance defect (must be rectified within a specified period), or a maintenance advisory (should be addressed at next scheduled maintenance).
  • Provide photographic evidence for significant findings.
  • List any test results with the instrument reading against the pass criterion.

The report is the document you rely on to demonstrate due diligence in the event of an incident. Keep reports for a minimum of 5 years.

How much does a commercial electrical inspection cost in Melbourne?

Small retail or office premises (under 300 m²): $350–$700 for inspection and written report. Larger premises or those requiring thermal imaging: $700–$1,800. Test and tag (appliance testing) is priced per item - typically $3–$7 per item for volumes over 20 items. Combine the inspection with test and tag to save mobilisation costs.

Electrical compliance obligations for different commercial premises

Commercial electrical compliance is not one-size-fits-all in Victoria. The obligations vary depending on occupancy type, the age of the building, and whether the premises are a lease or owner-occupied. Understanding which obligations apply before booking an inspection helps you get the most relevant scope.

Leased commercial tenancies

Under the Retail Leases Act 2003 and the broader commercial leasing framework in Victoria, landlords are generally responsible for ensuring the base building electrical infrastructure is safe and compliant. Tenants taking fitout works — installation of new circuits, lighting, or data infrastructure — need their own licensed electrician to issue a Certificate of Electrical Safety (CES) for those works. An incoming tenant audit can confirm what the landlord handover included versus what is the tenant’s responsibility going forward.

Food businesses and hospitality venues

Commercial kitchens attract specific electrical requirements including dedicated circuits for large cooking equipment, compliant exhaust fan wiring, and RCD protection on all circuits serving wet areas. A pre-opening compliance audit is a standard step for any food premises requiring a council registration in Victoria.

Offices and professional services

Office fitouts often have a high density of IT infrastructure requiring dedicated circuits and surge protection. Offices with server rooms or UPS systems benefit from an annual compliance check to ensure load distribution is still within breaker ratings as equipment is added over time.

The Energy Safe Victoria workplace electrical safety section covers employer obligations for electrical safety in commercial premises under the Occupational Health and Safety Act 2004.

Industrial and manufacturing premises have additional compliance layers under the Electricity Safety Act 1998 including mandatory inspection periods for high-voltage equipment and switchgear. For any commercial premises with three-phase distribution, transformer rooms or high-voltage supply, confirm that the electrician you engage holds the relevant endorsements for that classification of work.

FAQ

Is a commercial electrical inspection mandatory in Victoria?
There is no mandatory annual inspection for all commercial premises, but the OHS Act requires employers to maintain electrical equipment in safe condition. In practice, this means inspections should occur whenever there is reason to believe electrical conditions may have changed - new tenancy, post-flood, post-fire, structural work, or when employees report concerns.
Who is responsible for electrical compliance in a leased commercial space?
Both the landlord and the tenant have obligations, which are typically split in the lease. Broadly: the landlord is responsible for the building's fixed electrical installation; the tenant is responsible for portable appliances and equipment they bring in. This should be confirmed in the lease document - advice from a solicitor is appropriate where responsibilities are unclear.
Can I use any electrician or does it need to be accredited?
Any Victorian licensed electrical contractor can conduct an electrical inspection. For test and tag, the work can be done by a licensed electrician or a competent person trained in AS/NZS 3760 (this can include non-electricians in some circumstances). AFSS-related testing of emergency systems should be done by a competent person with knowledge of AS/NZS 2293.2.

For local help, see our Melbourne electrical services, electrician in Richmond, electrician in Melbourne CBD. Our emergency electrician in Richmond page covers scope, pricing and 24/7 dispatch. Emergency? See our emergency electrician in Richmond. Related guides: Pre-purchase electrical inspection Melbourne - what's checked and why it matters, Commercial AC failure in a Melbourne shop - your fastest path back to trading.

Need a Melbourne electrical technician?

We're one call away — 24/7 emergency service, live answer, upfront pricing.