If your AC was installed before 2015, it likely runs R22 or R410A - both already phased out or restricted in Australia. R32 (current standard since around 2014) is also on a phase-down path under HFC regulations. The honest answer for older systems: you can't convert them. When refrigerant leaks happen, the cost gap between regas and replacement is closing fast.
The refrigerant timeline
| Refrigerant | Era | Status now |
|---|---|---|
| R22 (HCFC) | Pre-2010 | Banned new import - regas extremely expensive |
| R410A (HFC) | 2005-2015 | Being phased down - cost rising sharply |
| R32 (HFC, lower GWP) | 2014-present | Currently dominant, on long-term phase-down |
| R454B / R290 (HFO blends, hydrocarbons) | 2024+ | Emerging - new installs starting to use |
What "phase-out" actually means for your existing system
Phase-out doesn't mean your system stops working. It means:
- The refrigerant in your unit is no longer being imported in bulk.
- Wholesale cost of that refrigerant rises year-on-year (R22 has gone from ~$80/kg to over $400/kg in 10 years).
- Licensed techs may decline to top up severely leaking systems - it's reportable as wasted HCFC.
- Replacement parts (especially TX valves and accumulators specific to that refrigerant) become harder to source.
Can your old system be converted? (Honest answer: usually not)
R22-to-R410A conversion is technically possible but rarely makes financial sense. Conversion requires:
- Complete oil change (R22 uses mineral oil; R410A needs POE oil - incompatible)
- New TX valves or capillary tubes
- Possibly new compressor (R410A runs at higher pressure)
- Full system pressure testing and recommissioning
Cost: $2,500-$5,500 on a system that may be 12-18 years old. For that money you can install a new, more efficient R32 split. Honest call: replace, don't convert.
Signs your AC is running on phased-out refrigerant
- System installed before 2010 - almost certainly R22
- System installed 2005-2014 - likely R410A
- System installed 2014+ - likely R32
- Check the data plate on the outdoor unit - refrigerant type is printed
- Brand-specific: Older Daikin, Mitsubishi Electric, Fujitsu pre-2014 mostly R410A
Cost impact - regas getting more expensive
| Refrigerant | Regas cost (typical split, 1kg) |
|---|---|
| R22 | $450-$850 + service - if available at all |
| R410A | $280-$480 |
| R32 | $180-$320 |
| Full system replacement (7kW split) | $2,500-$3,800 |
When R22 regas costs $850 and you'd need it again in 18-24 months because there's a leak, replacement starts to look like the cheaper option over 3 years.
What to do now if your system uses legacy refrigerant
- Don't replace pre-emptively if it's working fine. A leak-free R410A system has years of life left.
- Get a service inspection. Licensed tech checks for early leak signs.
- Plan replacement budget. Know what a new R32 system in your size would cost.
- Don't bother with conversion. Replace at end of life.
- Consider rebates. Energy efficiency upgrades sometimes qualify for VEU certificates.
ARC licensing - why only licensed techs handle refrigerant
Under the Ozone Protection and Synthetic Greenhouse Gas Management Act, only ARC-licensed (Australian Refrigeration Council) technicians can purchase, handle and dispose of refrigerant. This is non-negotiable. An unlicensed person handling refrigerant faces personal fines up to $24,000+. Always check the tech's ARC card - they're required to display it.
The official source for refrigerant rules is the Australian Refrigeration Council (arctick.org).
R32 in Melbourne: what you need to do now
Which Melbourne split systems use R32 refrigerant
R32 is the current standard refrigerant in most split system air conditioners sold in Australia from 2016 onward. Major brands including Daikin, Mitsubishi Electric, Fujitsu, Panasonic, and LG have predominantly switched to R32 for residential split systems. If you have a split system installed after 2016, it almost certainly uses R32. If your system was installed before 2016, it likely uses R410A (no current phase-out) or the older R22 (fully phased out; illegal to import new R22 refrigerant in Australia since 2020).
What the R32 phase-down means for your Melbourne aircon
Under Australia’s obligations under the Kigali Amendment to the Montreal Protocol, R32 production and import volumes are being progressively reduced. The practical effect for Melbourne homeowners is:
- R32 refrigerant will remain available for servicing existing systems throughout the transition period (2025–2035)
- New systems sold from approximately 2027–2030 will increasingly use lower-GWP alternatives such as R290 (propane) or R454B
- If your R32 system develops a refrigerant leak, repair it promptly — refrigerant costs will increase as phase-down progresses
- ARC-licensed technicians are required to recover and properly handle R32 — it cannot legally be vented to atmosphere
R32 safety information
R32 is classified A2L — mildly flammable at high concentrations. In normal split system operation, the amounts involved are small and the risk is minimal. However, a significant refrigerant leak indoors combined with an ignition source is a theoretical risk. For this reason, AS/NZS 5149 (the Australian/New Zealand refrigerating systems standard) specifies minimum room volume requirements for indoor units. A licensed installer ensures compliance. If you smell a faint sweet odour near your indoor unit, call 24/7 Service Mate for a refrigerant leak check.
R32 system maintenance and leak detection
Annual maintenance of your R32 split system extends its lifespan and catches refrigerant leaks early. During a service, a licensed ARC technician checks refrigerant charge level using manifold gauges, inspects the indoor evaporator coil and outdoor condenser coil for fouling, checks electrical connections, cleans filters, and verifies the drainage system. A low refrigerant charge almost always indicates a leak rather than normal consumption — refrigerant does not get used up. If your split system is not cooling as well as it did when installed, a refrigerant level check is the first diagnostic step. 24/7 Service Mate’s Andy and the HVAC team cover all Melbourne suburbs for split system servicing and R32 refrigerant top-up where a leak has been located and repaired. Call 1300 24 11 47 for a service booking.
If you are unsure which refrigerant your system uses, the type is printed on the outdoor condenser unit label alongside the system model number. R32 systems are labelled clearly. ARC-licensed technicians at 24/7 Service Mate are trained and certificated to work with R32 refrigerant across all Melbourne suburbs.
FAQ
- Will my R410A system stop working in 2030?
- No - it will keep running until it fails. The cost of repairing it rises over time.
- Is R32 dangerous?
- R32 is mildly flammable (A2L classification) but safe when handled by licensed techs and used in properly designed systems.
- Can I top up my own AC?
- No - illegal without ARC licence. Heavy personal fines.
- How do I know if my AC is leaking refrigerant?
- Decreased cooling, ice on the lines, hissing sounds, oily residue around fittings.
- Will my next system be R32 or R454B?
- In 2026, R32 still dominates Australian residential installs. R454B and propane (R290) are emerging mainly in commercial.
Related reading
For local help, see our Melbourne HVAC services, HVAC in Box Hill and HVAC in Glen Waverley. Our split system service and repair page covers what we check at routine services. For decision context, read split system vs ducted Melbourne.
Old system, low cooling?
Call 1300 24 11 47. ARC-licensed techs. Honest regas vs replace assessment.