Reverse cycle does both jobs with one outdoor unit. Switching mode is a controller setting, not a plumber visit — unless the unit was icing, leaking or tripping all winter and you are about to ask it to work harder in the opposite direction.
The short version
- Changing mode is a remote setting. It is not a plumber or technician visit.
- Do it on a mild day, not on the first 36°C afternoon when everything has to work immediately.
- Check the filters, the outdoor unit and the drain before you trust it for summer.
- Water on the floor, ice on the pipes, or a unit that trips the breaker is a fault, not a setting problem.
- Do not flick between heat and cool every few minutes. Give the compressor time to settle.
What the machine is doing
A reverse-cycle system moves heat. In heating, it pulls heat from outdoor air and delivers it inside. In cooling, a reversing valve flips the flow so the indoor coil becomes the cold one and the outdoor coil dumps the heat. The refrigerant, compressor and fans are the same. Only the valve and the controls change.
That reversing valve has sat in one position all winter. The first few changes of the year are when a sticky valve, a weak solenoid or a marginal capacitor shows itself. The machine does not “forget” how to cool, but it can fail to start the changeover, and then the unit blows lukewarm air or short-cycles.
The right order for the first switch
- Turn the system off at the remote. Wait five minutes so pressures equalise.
- Wash the indoor filters. Clean them in cool soapy water, dry them and refit them.
- Look at the outdoor unit. Clear leaves, cobwebs and mulch from the fins and the base. Check the drain outlet is not blocked.
- Select cool mode, set 24°C and fan auto. Do not start at 16°C. A big step demands a lot from a cold start.
- After ten minutes, feel the supply air at the indoor head. It should be clearly colder than room air. Put a hand near the outdoor fan: warm air should be blowing out.
- Check for drips at the indoor unit and the drain pipe outlet.
First-day faults we see in November
- No cooling, fan running: a reversing valve that did not shift, low refrigerant, or a failed sensor.
- Water dripping from the indoor head: a drain that blocked with winter dust or algae. Related: aircon leaking water indoors.
- Ice on the indoor coil or pipe: restricted airflow or low charge. Related: AC ice on lines.
- Musty smell when the fan starts: damp coil and a dirty filter. Related: aircon smells bad.
- Outdoor unit tripping the breaker: a tired capacitor, a loose connection or a compressor drawing too much. Do not keep resetting it.
When not to switch back and forth
Melbourne has the classic spring pattern: 14°C in the morning, 30°C in the afternoon, 12°C overnight. It is tempting to swap modes daily. Do not. Each change asks the compressor to restart against equalising pressure, and many units lock out the compressor for a few minutes to protect it. Use auto mode if your remote has it, or choose one mode per day. A fan-only day when the weather is mild is a legitimate way to test airflow without stressing the compressor.
Also avoid cooling with windows open. It wastes energy, and humid air condenses more on the coil, which increases drain loads and mould risk. See humidity and mould in aircon.
Ducted reverse cycle vs split
The change is the same on a ducted system, but dampers and zones complicate it. Zones that were closed for winter should be opened for cooling checks, and the return filter should be inspected because a filter that is half-blocked in winter becomes a freezer in summer. A ducted system in a roof space also has a heat load on the ducts: undersized or old flexible duct that coped with heating can sweat or underperform when pumping cold air through a 45°C roof.
Why a service before summer pays off
A technician can catch weak capacitors, slow fans, partial refrigerant leaks and drain problems in a quiet period. Waiting until the first 38°C day means a wait of several days for the same visit. A pre-summer service is a small cost compared with a system that fails at its peak. Related: pre-summer aircon service checklist and how often to service aircon.
Cost guide for 2026
These are guides only; we quote after diagnosis.
- Pre-summer service and test: typically one to two hundred dollars for a single split.
- Drain clear and flush: often part of a service, or a small standalone charge.
- Capacitor or contactor replacement: commonly a few hundred dollars with parts.
- Leak find and regas: quoted after a pressure test; see aircon regas cost.
- Reversing valve repair: a bigger job, often compared against replacement on an older unit.
Energy and comfort settings for the first week
Use the sleep or eco settings if your remote has them, close curtains on west-facing windows in the afternoon, and run the unit for longer at a moderate setting rather than short blasts at the lowest temperature. Cool air from a split settles to the floor, so aim the louvre across the room instead of straight down. Check the swing setting and the fan speed, which many users leave on low from winter heating.
FAQ
- Should I run fan-only for a day first?
- Yes, if the weather is mild. It confirms airflow and the drain without asking the compressor to work.
- Why does the outdoor unit steam in winter then not cool in spring?
- Steam in winter is defrost mode, which is normal. A valve that stuck in heating position can look fine until you ask for cooling.
- Is 18°C on cool better?
- It is not faster. It uses more power and can ice the coil. 23–25°C with a fan is the sweet spot for most Melbourne homes.
- Ducted vs split switching?
- Same remote change, but ducted needs filters, zone settings and a roof check. A split mostly needs a clean filter and drain.
- Do you service before summer?
- Yes. Book early in spring for the best choice of time slots.
- Can I do the switch with the remote and walk away?
- Stay for the first ten minutes. If it is going to trip, leak or ice, you will see it in that window.