A brief dip when a washing machine motor kicks in can be voltage drop on a long, shared circuit. A flicker that also pops a safety switch, or happens when nothing large starts, is a loose connection until proven otherwise.
The short version
- A quick, tiny dip as a big motor starts can be normal, especially with older bulbs.
- A flicker that is deep, long, or accompanied by a buzz, smell or tripping is a fault.
- The usual suspects are loose connections, an overloaded circuit, a poor neutral and a supply issue at the street.
- Do not ignore flicker in an old house. Loose joints heat.
- Turn off the affected circuit if you smell anything hot.
Normal dip vs dangerous flicker
Every motor draws a surge when it starts. A fridge compressor, a washing machine drum, a split-system compressor and a garage door opener all pull more current for a second or two than they do running. On a healthy supply with decent cable, you see a slight dim you can only notice if you stare at the light. A deep dip, a sharp flash, repeated flickers while the appliance runs, or dimming across several rooms points to a problem somewhere between the street and the lamp.
LED lamps flicker for their own reasons. Cheap drivers, incompatible dimmers and the wrong bulb type produce flicker with no supply fault. If only one lamp flickers and others on the same circuit do not, change the lamp first. Related: flickering lights Melbourne and lights dimming when the aircon starts.
Laundry, kitchen and split-system inrush
Inrush is the surge at start. The laundry is a classic: a washing machine, a dryer and a heater on the same circuit pull a lot on a long, thin cable. Kitchens add kettle, toaster, microwave and oven. A split system adds an outdoor compressor. If the appliance shares a circuit with the lights, the voltage drop shows up in the lights first.
Modern inverter compressors have a soft start that reduces the dip, while older ones start with a hard kick. A 15-year-old split system and a 20-year-old washing machine on the same old circuit are the pairing we see most.
Loose neutral and other serious causes
The more worrying causes are:
- Loose neutral at the switchboard or the meter: lights go bright in one room and dim in another, or flicker with random load changes. It can damage appliances and is a priority.
- Corroded or overheated terminals at the board: flicker with heat or buzzing from the board. Related: hot switchboard buzzing.
- Loose connection in a ceiling rose or light fitting: flicker in one light, sometimes with a crackle.
- Service fuse or service wire problems: the supply to the house is the distributor’s equipment, and a poor connection there shows up as flicker house-wide.
- Neighbour or street issue: a faulty transformer or overloaded line gives flicker in several homes at once.
What you can check safely
- Note which appliance triggers it, and which lights flicker.
- Check whether neighbours see the same thing. If they do, call your distributor’s fault line, not us first.
- Try the appliance in a different room on a different circuit.
- Look at the switchboard. Do not open covers. If the board is warm or has a smell, turn off the main switch and call.
Do not run an extension lead from another room as a permanent fix. That adds another joint, adds heat and hides the symptom.
What we test
We measure voltage at a powerpoint with the appliance off, on and running. A drop of more than a few percent under load is a sign of a cable that is too long, too thin, or has a poor joint. We check terminals at the board and at the first outlet on the run, using a thermal camera if we suspect heat. We test the neutral and earth paths, and if the problem is at the street we document the readings so the distributor can act. Related: overloaded power points and summer electrical load.
Cost guide for 2026
Guides only; we diagnose first.
- Diagnosis visit with voltage drop test: usually a call-out plus an hour of labour.
- Re-terminating a loose joint at an outlet or the board: often a modest repair.
- New dedicated circuit for a heavy appliance such as a split system or dryer: commonly a few hundred dollars to over a thousand.
- Switchboard upgrade if the board is the weak link: from a couple of thousand dollars. See switchboard upgrade cost.
Seasonal and Melbourne-specific patterns
We see more calls in the first hot days of summer, when split systems and fans all start at once, and again during winter evenings when heaters, ovens and dryers run together. Storm season adds another angle: a surge or a water-damaged connection can turn a quiet fault into a visible flicker. See power out after a storm. If your flicker appeared right after a storm, treat it as urgent, since moisture in a joint can arc.
In homes with a granny flat, EV charger or new air conditioner, the combined load can push the old supply to its limit. A quick load calculation often explains a flicker that has started only since the new equipment arrived.
FAQ
- Is LED flicker always an electrical fault?
- No. Cheap drivers and incompatible dimmers cause plenty of it. We check the supply first, then the lamp.
- Can a service fuse cause this?
- Yes. A poor connection in the supply to the house shows as flicker everywhere. That is a job for the distributor and a licensed electrician together.
- Should I use an extension lead to another room?
- As a test, maybe. As a fix, no. It hides the cause and adds risk.
- Does a switchboard upgrade fix flicker?
- It can, if loose or corroded terminals in the old board were the cause. It will not fix a thin cable run or a street fault.
- Which suburbs see this most?
- Older housing stock in Footscray, Preston, Oakleigh and Coburg, and any home with an old board and a new air conditioner.
- Is it safe to keep using the appliance?
- If the flicker is mild and there is no smell, noise or tripping, yes for a short time. If it is deep, repeated or hot, switch the circuit off.
Related reading
See electrical, fault finding and electrical repairs, emergency electrician, electrician in Footscray and electrician in Oakleigh.
Lights flickering when the washing machine starts?
We test voltage and joints before we quote a fix. Call 1300 24 11 47.