A pressure relief valve (PRV / TPR valve) on a hot water service is a safety device, not a nuisance drip to plug. Some discharge during heating is expected on many systems; continuous running, steam, or pooling under the tank is not. Never cap a relief outlet — that turns a maintenance issue into a tank rupture risk.
Hot water valve dripping constantly?
Call 1300 24 11 47 — do not cap the relief pipe. We will check valve, expansion control and tank condition.
The short version
- Short discharges during heat-up can be normal expansion relief.
- Continuous flow from the drain line usually means a faulty valve, high pressure, failed expansion control, or a thermostat running too hot.
- Never seal or plug the relief outlet.
- Lift-lever tests belong to people who know how to reseat the valve — forced tests can create a leak that was not there.
- Replacement is a licensed plumber job; wrong pressure rating is dangerous.
What the PRV / TPR valve does
Storage hot water tanks heat water in a closed vessel. As temperature rises, water expands. The temperature-and-pressure relief (TPR) valve opens if pressure or temperature exceeds the valve’s rating, discharging to a drain line — often copper or plastic running to the outside or an tundish. That discharge protects the cylinder from catastrophic failure.
Many Melbourne installations also include an expansion control valve (ECV) on the cold inlet that handles day-to-day expansion more gently. When the ECV fails or is missing on systems that need one, the TPR may work overtime and appear “leaky.”
Normal drip vs problem leak
| Observation | Likely meaning |
|---|---|
| Occasional dribble during heating, then dry | Often normal expansion |
| Steady stream for hours | Fault — investigate |
| Hot water / steam from drain | Urgent — thermostat or element issue possible |
| Water under tank not from drain line | Cylinder leak — different problem |
| Drip only when somebody runs a tap | May be unrelated fitting; still check |
High mains pressure in some Melbourne streets, failed pressure-limiting valves, and ageing valve seats all push systems toward continuous discharge. A plumber measures static and dynamic pressure rather than guessing.
⚠ Do not cap the drain
Capping a relief line to “stop the waste” is extremely dangerous. If you need the drip stopped, call for correct diagnosis and parts — not a plug.
What a plumber checks
- Whether discharge is from TPR, ECV, or a tank seam
- Inlet pressure and any pressure-limiting/expansion valves
- Thermostat settings and evidence of over-temperature
- Age and condition of the cylinder (replace valve on a dying tank is poor value)
- Correct valve rating and discharge pipe installation on replacement
Guide costs: TPR or ECV replacement often a few hundred dollars including labour; adding or replacing a pressure-limiting/expansion set costs more; a corroded tank shifts the conversation to replacement — see hot water replacement costs.
Apartment and cupboard installations
Internal cupboards need a correctly terminated drain. A valve dripping into a cupboard tray may be the only warning before particleboard floors swell. If the drain terminates on a balcony above neighbours, continuous discharge becomes a strata complaint as well as a water bill issue — fix the cause, do not redirect into a plant pot.
How 24/7 Service Mate handles PRV leaks
We distinguish safety discharge from faults, measure pressure, and quote valve versus system replacement honestly. Related: no hot water overnight, hot water no pressure.
Pressure, ECVs and why Melbourne mains matter
Some Melbourne streets run relatively high static pressure. Combined with a non-return valve on the meter or a pressure-limiting setup that has failed, expansion during heat-up has nowhere to go except out a relief valve. Replacing the TPR alone without measuring pressure often recreates the drip in months. A complete look includes static pressure, any existing limiting valve, the expansion control valve, and whether the discharge pipe is correctly sized and terminated.
Heat-pump and solar-boosted cylinders still need correctly rated relief devices. If a recent upgrade changed the cylinder but reused an old valve or left the drain tied into an illegal point, we correct that as part of making the system safe — not as an optional extra to ignore.
Water bills, strata trays and neighbour complaints
Continuous PRV discharge shows up as unexplained water use and, in apartments, as balcony drips onto living spaces below. Do not relocate the drain into a plant pot or bucket as a “solution.” Fix the valve and pressure arrangement. If a cupboard tray is catching the drip, empty it and call — trays overflow silently onto particleboard floors overnight.
When a tank is near end of life and the valve is weeping, compare valve-only repair against replacement. Putting a new valve on a corroding cylinder can be throwing good labour after bad; we will say so with the tank’s age and leak history in view.
Test levers, reseating failures and scald risk
Operating the TPR test lever can leave the valve dripping if scale prevents reseating. That is why casual monthly lever tests without knowing how to stop a stuck-open valve create emergency calls. If you have already lifted the lever and now have a continuous discharge, isolate the tank’s power or gas and cold inlet if safe, and call — do not cap the drain.
Over-temperature events that send very hot water from the drain need thermostat investigation, not only a new valve. Scald risk at fixtures also rises if tempering valves have failed in parallel. We check the safety chain as a system.
Connecting PRV issues to tank age decisions
A ten-year-old dripping tank with rust at the base is a replacement conversation. A three-year-old tank with a weeping valve and high street pressure is a valve and limiting-valve conversation. Bring the manufacture sticker photo when you call so we arrive with the right expectation and parts range.
FAQ
- Is a leaking PRV wasting a lot of water?
- Continuous discharge can waste thousands of litres a year and signal a safety fault. Occasional expansion drips are minor by comparison.
- Can I replace the valve myself?
- No — incorrect installation, wrong rating, or poor sealing risks scalding and tank failure. Use a licensed plumber.
- Should I operate the test lever monthly?
- Manufacturer advice varies. Operated incorrectly, levers fail to reseat and then leak continuously. If unsure, leave testing to a service visit.
- Why did it start after a new tap installation?
- Sometimes coincidental; sometimes non-return valves or tempering changes altered expansion paths. Worth a pressure check.
- Electric vs gas tanks — same valve idea?
- Both use temperature/pressure relief on storage cylinders. Continuous-flow units are different and usually lack this tank-style TPR arrangement.
Related reading
Explore our Melbourne plumbing services or see what is included in hot water repair and replacement. For more practical detail, read No Hot Water Overnight Melbourne: Quick Checks Before Calling a Plumber and Best Hot Water System Melbourne 2026: Heat Pump, Gas & Electric Compared.
Relief valve will not stop dripping?
Call 1300 24 11 47. We will make it safe without capping anything — and tell you if the tank is worth saving.