A copper pipe beside a storage heater that drips during heat-up can be normal expansion. A pipe that runs constantly, or steam, is a failed pressure-temperature valve or a heater that is overheating. Do not cap that pipe.
The short version
- A small drip while the heater heats up can be normal expansion.
- A pipe that runs constantly, steams or sprays is a fault. Switch off the heater and call.
- Never cap, plug or tape the overflow pipe. It is a safety path.
- The relief valve (PTR or PRV) is the part that releases pressure and temperature. Wear and scale make it weep.
- High mains pressure is a common hidden cause. Related: pressure limiting valve.
Which pipe
A storage hot water heater has a relief valve near the top, with a copper pipe running down the side to a safe discharge point, often a drain or the outside of the house. That pipe is the overflow or relief line. It is separate from the tank drain pipe near the bottom and from the expansion control valve on some systems. Check which one drips. Our guide on hot water PRV leaking covers the valve side in more detail.
On a heat pump, the same principle applies. The tank has a relief valve and an overflow line, and a heat pump unit also produces condensate, which drains separately. Do not confuse the two.
Expansion vs failure
When water heats, it expands. In a closed system, that expansion has to go somewhere, and a small volume can leave via the relief valve as a few drips while the heater heats up. That is normal if the drip stops within about an hour once the water is hot. A weep that continues all day, a pipe that runs steadily, steam, or a valve that sprays hot water points to a problem:
- Worn or scaled valve seat: the valve cannot seal fully and weeps.
- High incoming pressure: the valve lifts at its set point more often than it should.
- Thermostat failure: the water overheats and the temperature relief function trips.
- Missing or blocked expansion path: in some installations an expansion control valve is needed.
- Heater at end of life: corrosion and sediment make everything worse.
What you can do safely
- Check the pipe outlet: is it dripping a few drops, running steadily or spraying?
- Touch-test the pipe cautiously. If it is too hot to hold, back away.
- Place a bucket under the outlet to catch water and measure how much it produces per hour.
- Switch the heater off at the isolator if the pipe is steaming, running hard or the tank feels hotter than normal.
- Do not touch the valve lever. Lifting the test lever can cause a spray of scalding water.
Gas vs electric isolation
For an electric storage heater, turn off the circuit at the switchboard or the heater’s isolator. For a gas storage heater, turn the gas control to pilot or off, as per the manufacturer’s label, and leave the water supply on unless advised by a plumber. Do not shut the cold water to a hot tank while it is still heating, because pressure can rise. If you are unsure, call and we will talk you through it. For gas smells, follow gas leak emergency.
What a licensed plumber does
We measure incoming and tank pressure, check the valve rating, test thermostat operation, and inspect the tank and fittings for corrosion. If the valve is faulty, we replace it with an approved unit and run the discharge pipe correctly to a safe place. If pressure is high, we recommend a limiting valve. If the tank has failed, we say so. Related: hot water repair vs replace and hot water system types in Australia.
Cost guide for 2026
Guides only; we quote on site.
- Pressure test and diagnosis: often a standard call-out.
- Replacing a relief valve on an accessible storage heater: commonly a few hundred dollars with parts.
- Adding a pressure limiting valve: a quoted install, often several hundred dollars.
- Thermostat or element replacement on an electric heater: usually a few hundred dollars.
- Replacing the heater: a bigger decision. See hot water replacement cost 2026.
Why the overflow path matters in a Melbourne home
The relief line should discharge somewhere visible and safe, such as over a drain or a yard, because the water may be scalding. Many houses end the pipe inside a wall cavity, into a tray, or into a garden bed. Some owners, annoyed by a drip, tie the pipe into a bucket or cap it. That removes the safety path, and if the thermostat then fails, the tank can build pressure beyond its limit. Rental properties where a tenant has plugged the pipe are a surprisingly common find.
In ceiling-mounted or roof-space heaters, as in some Federation and 1960s homes, a leaking relief valve may drip onto the ceiling long before it appears on the ground. A brown ceiling stain below a laundry or hallway cupboard is worth investigating. See pipe burst water damage.
A good installation fits a tray with a drain under the heater, and a correct fall on the relief line. We often correct runs that were installed with a rise or a loop, which traps water and makes the valve behave oddly.
FAQ
- Can I put a bucket under it and wait?
- For an hour or two while you arrange a visit, yes. If the flow is steady or the water is steaming, switch the heater off and call.
- Gas vs electric isolation?
- Electric: turn off at the switchboard. Gas: set the control to off or pilot. Never switch off water to a hot, heating tank without advice.
- Heat pump overflow?
- Heat pumps have relief lines too. A drip can be normal expansion, but constant flow needs checking. See heat pump hot water cost.
- Is a dripping PTR wasting much water?
- A fast drip can waste hundreds of litres a month. It also hides pressure faults that shorten tank life.
- Roof tanks vs outdoor?
- Roof-mounted or ceiling-space heaters can flood the ceiling if the overflow is blocked. We check the tray and discharge path carefully.
- Can I replace the valve myself?
- No. It is licensed plumbing work, and a wrongly fitted valve is a scald and safety risk.